HI-85-11-2 — Effect of Insulation Joints on Heat Loss through Flat Roofs

Click here to purchase

Increased heat loss has been measured for several insulation joint arrangements in extruded ad polystyrene placed on a 9-mm thick plywood deck. Butt joints ranging up to 25.4 mm wide, a 3-mm butt joint bevelled to 28 mm at the deck, and a 3-mm shiplap joint were used. Most. of the work was carried out with protected-membrane roof arrangements, but measurements were also made on a conventional roof arrangement with 2.5- and 12.7-mm butt joints.

Sets of two and six heat flux transducers were placed at. the underside of the deck at various locations with respect to the insulation joints . The measured heat fluxes were used to estimate heat flux as a function of distance from the joint and from this to compare heat losses with and without joints.